EtherCAT AI Terminals parameters
Number of inputs
Power supply
Technology
Signal current
Signal voltage
Distributed clocks / Distributed clocks precision
Internal resistance
Input filter limit frequency
Dielectric strength
Conversion time
Resolution
Measuring error
Electrical isolation
Current consumption power contacts
Current consumption E-bus
Bit width in the process image
Configuration
Special features
Weight
Operating/storage temperature
Relative humidity
Vibration/shock resistance
EMC immunity/emission
Protect. class/installation pos.
Pluggable wiring
Approvals
Surge voltage resistance
Special features:
Measuring voltage
Measuring range, technical
Measuring range, nominal
Measuring current
Common-mode voltage UCM
EtherCAT AI special features:
Surge voltage resistance
Common-mode voltage UCM
Measuring range, nominal
Measuring range, technical
Measuring current
Measuring voltage
 
EL3061
 
1 (single-ended)
via the E-bus
single-ended
0…10 V
> 130 kΩ
1 kHz
12 bit (16 bit presentation, incl. sign)
0.625 ms default setting, configurable
< ±0.3 % (relative to full scale value)
500 V (E-bus/signal voltage)
typ. 130 mA
max. 30 V
inputs: 4 byte
activatable FIR/IIR filters, limit value monitoring
approx. 60 g
-25…+60 °C/-40…+85 °C
95 %, no condensation
conforms to EN 60068-2-6/EN 60068-2-27
conforms to EN 61000-6-2/EN 61000-6-4
IP 20/variable
for all ESxxxx terminals
CE, UL, Ex
-
-
-
-
-
-
-
 
-
-
-
-
-
-