NOT Authenticated
 
EtherCAT Box Analog inputs parameters
Number of inputs
Input connections
Protocol
Bus interface
Signal type
Internal resistance
Common-mode voltage UCM
Resolution
Measuring error
Input filter limit frequency
Conversion time
Nominal voltage
Distributed clocks
Input filter
Sensor supply
Current consumption from US
Power supply connection
Bit width in the process image
Electrical isolation
Special features
Weight
Operating/storage temperature
Vibration/shock resistance
EMC immunity/emission
Protect. class/installation pos.
Approvals
 
EP3356-0022
 
2, for 1 resistor bridge in full bridge technology
M12, screw type
EtherCAT, TwinCAT SC
2 x M8 socket, shielded, screw type
resistor bridge, strain gauge
> 200 kΩ (UREF), > 1 MΩ (UD)
-
24 bit, 32 bit presentation
< ±0,01 % for the calculated load value in relation to the final load value with a 12 V feed and 24 mV bridge voltage (hence nominal strain gauge characteristic value of 2 mV/V), self-calibration active, 50 Hz filter active
10 kHz low pass (-3 dB)
0.1…250 ms, configurable, max. 10,000 samples/s
24 V (-15 %/+20 %)
yes
-
10 V (supplied by the EP3356)
120 mA
feed: 1 x M8 male socket, 4-pin downstream connection: 1 x M8 female socket, 4-pin
-
-
self-calibration, quadruple averager, dynamic filters, fast data sampling, parallel connection
-
-25…+60 °C/-40…+85 °C
conforms to EN 60068-2-6/EN 60068-2-27
conforms to EN 61000-6-2/EN 61000-6-4
IP 65/66/67 (conforms to EN 60529)/variable
CE, UL

© UAB "SANTAVILTĖ"